CYX50 series oil injection core pressure sensors use internationally advanced high-stability, high-precision silicon pressure chips, adopt stress-optimized design sintering seat, through patch, gold wire bonding, diaphragm pure plane welding, high vacuum oil injection, pressure cycle to Production by stress, high temperature aging, temperature compensation and other processes. The assembly size and sealing method of CYX50 series conform to the international 50 chuck…

SKU: CYX50-en. Category:

1 Overview

CYX50 series oil injection core pressure sensor adopts international advanced high stability and high precision silicon pressure chip, adopts sintering seat of stress optimization design, through patch, gold wire bonding, diaphragm pure plane welding, high vacuum oil injection, pressure circulation to Production by stress, high temperature aging, temperature compensation and other processes.

The assembly size and sealing method of CYX50 series conform to the international 50 chuck interface standard, and have good interchangeability. It is mainly used in medicine, food and other industries with high cleanliness requirements for pressure testing.

 

2 Product features

 ● Measuring range -100kPa~0kPa~10kPa…6MPa
 ● With gauge pressure G, absolute pressure A and sealed gauge pressure S
 ● Constant current/constant voltage power supply
 ● Isolated structure, suitable for a variety of fluid media
 ● Φ50.5mm standard pressure oil injection core
 ● All 316L stainless steel

3 Main uses

 ● Pharmaceutical and food industry process control

 ● gas and liquid pressure measurement

 ● gas and liquid pressure measurement

 ● gas and liquid pressure measurement

4 Technical indicators

4.1 Electrical performance

 ● Power supply: ≤3.0mA; DC≤10V DC
 ● Electrical connection: 0.2mm2 four-color 100mm silicone rubber flexible wire
 ● Common mode voltage output: 50% (typical value) of current input, 40% (typical value) of voltage input
 ● Input impedance: 2.7kΩ~5kΩ
 ● Output impedance: 3.0kΩ~6kΩ
 ● Response time (10%~90%): <1ms
 ● Insulation resistance: 500MΩ/100V DC
 ● Allow overvoltage: 1.5 times full scale

4.2 Structural performance

 ● Diaphragm material: stainless steel 316L
 ● Shell material: stainless steel 316L
 ● Pressure tube material: stainless steel 316L
 ● Pin Lead: Gold-plated Kovar
 ● · Sealing ring: Silicone rubber
 ● Net weight: about 160g

4.3 Environmental conditions

 ● Vibration: no change under 10gRMS, (20~2000) Hz
 ● Constant acceleration: 100g, 11ms
 ● Media compatibility: 316L and silicone rubber compatible liquid or gas

4.4 Benchmark conditions

 ● Medium temperature: (25±3)℃
 ● Ambient temperature: (25±3)℃
 ● Humidity: (50%±10%) RH
 ● Environmental pressure: (86~106) kPa
 ● Power supply: (1.5±0.0015) mA DC

4.5 Standard range sensitivity output and optional pressure form

Range

full rangeOutput (mV)

Pressure form

 

Range

full rangeOutput (mV)

Pressure form

0~10kPa

(30~120) ±20

G

0~400kPa

(40~150) ±20

G/A

0~35kPa

(40~120) ±20

G/A

0~1.0MPa

(55~145) ±20

G/A

0~70kPa

(20~140) ±20

G/A

0~2.0MPa

(50~160) ±20

G/A

0~100kPa

(50~145) ±20

G/A

0~3.5MPa

(60~150) ±20

G/S/A

0~200kPa

(30~125) ±20

G/A

0~6.0MPa

(60-130) ±20

S

 

4.6 Basic parameters

Parameters

Typical value

Maximum

Single

Full scale output

100

250

mV

Zero output

±1

±2

mV

Non-linear

0.2

0.5

%FS

Late

0.05

0.08

%FS

Repeatability

0.05

0.08

%FS

Input/output impedance

2.6

5.0

Zero temperature drift 1

±0.4

±1.0

%FS,@25℃

Sensitivity temperature drift 2

±0.4

±1.0

%FS, @25℃

Long-term stability

0.2

0.3

%FS/year

Excitation current

1.5 (Maximum input voltage 10V)

mA

Insulation resistance

500(100VDC)

Compensation temperature Note 3

0~50;-10℃~70℃

Operating temperature

-40~+125/150

storage temperature

-40~+125

Response time

≤1

ms

Housing and diaphragm materials

316L stainless steel

 

O-ring

Silicone Rubber

 

Measuring medium

Fluid compatible with 316L, silicone rubber

 

Life (25℃)

>1×108 pressure cycle (80%FS)

Times

Filling medium

Silicone oil

 

Sealing ring

Various specifications, customized by users

 

Note 1, Note 2: The typical value of zero to 10 kPa temperature drift and sensitivity temperature drift is 0.5%FS@25℃, and the maximum value is 1.2%FS@25℃.

Note 3: For 200kPa and below ranges, the compensation temperature is 0~50℃; for more than 200kPa, the compensation temperature is -10℃~70℃.

 

 

5 Type selection structure

5.1 Core model selection model and outline drawing

  

  

  

  

CYX50

-100kPa~7MPa

CYX5001

(-40℃~125℃)

06-1.png

CYX5002

(-40℃~150℃)

06-2.png

   

6 Schematic diagram and wiring

   连接图.png

 

IN+(red line)-power supply positive IN-(black line)-power supply negative S+(yellow line)-output positive S-(blue line)-output negative

 

7 Application tips

Pay attention to protect the front diaphragm of the pressure core and the compensation circuit board at the rear end, so as not to damage the performance of the pressure core or damage the core.
● Do not press the metal diaphragm with your hands or hard objects to avoid damage to the core due to chip deformation or perforation.
● The vent pipe at the rear of the G-type core body should be kept open to the atmosphere; it is forbidden for water, water vapor or corrosive media to enter the reference cavity at the rear of the core body.
● Avoid dropping, bumping, etc., which will affect the stability of the product.
●  If there is a change in the pin lead, the actual physical label of the core shall prevail.

 

8 Selection guide

QQ截图20200526195044.png

*工艺标识:f表示通用工艺,Y表示负压工艺。